• SLP CS 25

    Article No. 027301

    SLP CS 25 / 30 / 50

    Calcium silicate interior insulation board for thermal building renovations

    Dimensions (length x breadth)
    1000 mm x 500 mm, thickness 25 mm (± 2 mm)
    Variant
    0273 | SLP CS 25 / 30 / 50
    Size / Quantity

    Product specifications

    Aw value / water absorption coefficient Approx. 77.4 kg/(m²*h0.5)
    Flexural tensile strength Approx. 1.1 N/mm²
    Compressive strength Approx. 2.0 N/mm²
    Porosity Approx. 85 vol%
    w80 220 kg/m³
    Thermal conductivity (λ10,dry,mat.) Approx. 0.073 W/(m*K)
    Water vapour diffusion resistance coefficient µ 5
    wsat 951 kg/m³
    Dry density Approx. 300 kg/m³
    Reaction to fire class A1

    The stated values represent typical product characteristics and are not to be construed as binding product specifications.

    Field of application

    • For use indoors
    • Mould control and prevention in existing buildings
    • Implementation of the hygienic minimum heat insulation level in existing buildings
    • Improving the room climate by increasing the wall surface temperature

    Properties

    • Thermally insulating and mould inhibiting
    • Enables water vapour diffusion
    • Capillary-active
    • Free from quartz sands and quartz powders
    • Thermal conductivity (nominal value) approx. 0.07 W/(m*K)
    • Reaction to fire class A1 (non-combustible)
    • Low construction height
    • Preparation
      • Substrate requirements

        The substrate must be clean and capable of bearing a load.

        The substrate must be level.

      • Preparations

        Level off and even out highly uneven substrates – use SP Level to close up joints and even out surfaces.

    • Application
      • Jigsaw / Cutter
      • Pre-wet the substrate.

        Apply SLP Fix as a scratch coat on the rear face of the board and on the substrate.

        Using a toothed spatula, apply SLP Fix wet-on-wet to the rear face of the panel and to the substrate.

        Position and press on the boards from the bottom up.

        Align using a floating rule.

    • Application instructions
      • Mark the desired dimensions on the board.

        Cut using a jigsaw or hand-held circular saw.

        Rework the cut edges with a rasp or file if necessary.

        Avoid cross joints.

        Make sure that full-surface bonding is achieved.

    • Working tools / cleaning
      • Jigsaw / Cutter
      • Cutter knife and keyhole saw

    • Storage / shelf life
      • Store frost-free / close containers
      • Dry and frost-free.

    • Usage
      • 2 panels/m²
      • 2 boards/m²

    • General information
      • Current regulations and legal requirements must be taken into account and deviations from these must be agreed separately.

        The relevant test certificates must be observed when planning and carrying out work.

    • Disposal instructions
      • The product must be disposed of in accordance with the official regulations.

    Different variants