Article No. 092084
Two-component corrosion protection for reinforcement steel in concrete repairs
Product specifications
The stated values represent typical product characteristics and are not to be construed as binding product specifications.
Field of application
- Long-term corrosion protection coating for bare or exposed reinforcing rods and other steel elements in concrete restoration
Properties
- Resistant to condensation, chloride and sulphate ions
- Excellent adhesion capacity
- Low solvent content
- Pore-free drying
-
Preparation
-
Substrate requirements
Remove rust and rolling skin from steel surfaces e.g. by sandblasting SA 2 1/2.
The substrate must be clean, dust-free and dry.
-
-
Preparation
-
Combination container
Add the entire quantity of the hardener (component B) to the base compound (component A).
Use a wooden stick or spatula to stir the mixture until even.
Mix for at least 3 minutes.
-
Application
-
As a general principle, higher temperatures will reduce and lower temperatures will increase the times stated.
Apply the prepared mixture over the entire surface using suitable means.
Once the first layer has cured, apply a second layer.
Blind the second layer while wet with fire-dried quartz sand, grain size 0.1–0.4 mm.
-
Working tools / cleaning
-
Brush, mixer
-
More detailed information can be found in the Remmers Tool Programme.
Clean tools and remove any contamination immediately after use and while fresh using Thinner V 103.
Take suitable protective and waste disposal measures when cleaning.
-
Storage / shelf life
-
If stored in unopened original containers in a cool, dry and frost-free place, the product will keep for min. 9 months (component A) or 24 months (component B).
-
Usage
-
Approx. 0.35 kg/m² per coat
-
General information
-
Unless otherwise specified, all of the values and application rates given above have been determined under laboratory conditions (20 °C). Slight deviations from these values may arise if the product is worked with on site.
Only for use on small surface areas!
Blind any impurities in the concrete surface with PC S-Protect 2K while wet.
Further notes on working, system construction and maintenance of the listed products can be found in the latest Technical Data Sheets and the Remmers system recommendations.
-
-
Disposal instructions
-
Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.
-
-
Safety / regulations
-
For professional users only!
Further information concerning safety during transport, storage and handling as well as on disposal and ecology can be found in the latest Safety Data Sheet.
-